Introduction to Fire Dynamics Simulator and Smokeview
October 15-17, 2008
Instructor(s): Paul F. Hart, P.E., FSFPE and Dr. David Sheppard
This 2 1/2 day course is intended for engineers with a strong background in fluid dynamics and fire dynamics.
The Fire Dynamics Simulator is the newest and most versatile of the fire models developed by NIST. The Fire Dynamics Simulator has been used for many types of problems like sprinkler activation in warehouse fires, tenability in residential fires, and smoke concentration in outdoor pool fires.
The NIST Fire Dynamics Simulator consists of two programs - FDS and Smokeview. The NIST Fire Dynamics Simulator predicts smoke and/or air flow movement caused by fire, wind, ventilation systems etc. Smokeview visualizes the predictions generated by FDS.
FDS, a computational fluid dynamics (CFD) model, solves a form of the Navier-Stokes equations appropriate for low-speed, thermally-driven flows of smoke and hot gases generated in a fire. FDS has integrated sub models that calculate many fire related phenomena such as radiative and convective heat transfer, sprinkler activation and sprinkler sprays, mixture fraction combustion, and many others.
This is a hands-on seminar, if the software does not run on your computer then you will not fully benefit from the class. Attendees must bring a laptop computer with a minimum 1 GHz Pentium processor, 256 MB of RAM and 2GB of free hard disk space. The computer should have a spreadsheet program for analyzing data and Adobe Acrobat for reading the documentation. The attendees should also make sure that they have sufficient security privileges on their computers to allow the software to be installed during class.
Before coming to class, attendees should download Version 5.1.6 of FDS and Smokeview software from the NIST website and make sure the programs run on their computer. The NIST website is http://www.bfrl.nist.gov. Follow the links for software, fire simulation software, and the NIST Fire Dynamics Simulator and Smokeview.
Outline:
Earn Valuable CEUs:
The Society of Fire Protection Engineers will award 2.00 Continuing Education Units for attending the entire seminar.
Registration:
Advance Registration Fees (Must be received by Monday, September 22, 2008)
$685 SFPE Members $825 Non-Members
Late Registration Fees (Received after Monday, September 22, 2008)
$760 SFPE Members $925 Non-Members
There are three easy ways to register:
-
Register online: Joining online is fast and convenient using your credit card. We accept Visa, MasterCard and American Express.
-
-
Contact Julie Gordon at SFPE Headquarters at +301 718-2910 ext. 104.
Special Offer! Register for one seminar and receive a 25% discount on any additional seminar of equal or lesser value. Discount NOT available via the online registration.